Appendix B Profinet Communication Card Usage Instructions - Veikong VFD500 Series User Manual

High performance vector and torque control frequency inverter
Hide thumbs Also See for VFD500 Series:
Table of Contents

Advertisement

VFD500 high performance vector control frequency inverter user manual Appendix B Profinet communication card usage
2. Set instructions
Recommended setup method:
Install the PN card and power on the drive.
1.
2.
P30.02=7 Modify the baud rate to 115200 (terminal RS485 fails, do not connect 485+/485-
terminal).
3.
P00.06=2 is modified to communication initiation.
P01.00=7 is modified to communicate with a given frequency.
4.
P30.14=1 is modified to 0.01H z units (for example, when the maximum frequency is 5
5.
0.00Hz, the actual setting frequency after setting 4 325 is 4 3.25H z, if P30.14=0, set 5
000, corresponding to the setting frequency of 50Hz* 5000/10000=25Hz).
Set the network name of drive PN, modify P32.0 0=1 to set 1'255 according to the device
6.
order, and the network name is mtpn-1/ mtpn-2... mtpn-255.
To set the MAC address, please modify P32.05~P32.07, it is recommended to set it
7.
sequentially according to the order of the device. Setting P32.07=0 x 0010 (recommended
setting method 0 x 0020/0x0030...) 0x00A0... 0x00B0... 0x0100) The lowest digit is not
recommended to be set (the port will occupy the M AC address may cause address
conflicts, and there is no fault prompt when a conflict occurs), and the MAC address takes
effect after power on again (it is recommended not to modify P32.05).
8.
After powering back on and waiting for the PN card to power on, the internal data refresh
is expected to take 10s~20s.
9.
Through the corresponding configuration of the device name in the host computer such as
PLC (it must be consistent with the drive, otherwise there will be a communication
abnormality), modify the I P address and subnet mask (usually the mask is 2 55.255.255.0,
and the default IP address is 1). 92.168.2.101).
After the configuration is complete, see Chapter 4 Configuring the PZD Address.
Function
name
code
Source
P00.06
operation
command
Main frequency
P01.00
source
selection
Communication
P30.14
special register
speed unit
PN card network configuration:
The network configuration can be modified in two ways: 1. Host computer configuration; 2.
Table 2_1
Function code setting table
of
0:keyboard
1:terminal
2:communication
0:Digital setting
1:Ai1
2:AI2
3:Ai3(IO extension card)
4:Ai4(IO extension card)
5:HDI
6:multi-step speed
7:communication
0:0.01%
1:0.01hz
2:1rpm
- 149-
description
Default
0
0
0