Chapter 5 Function code
27.03), press the 【SHIFT】 key on the keyboard to switch between the two monitors, as shown below.
P21.12 = 0052
Monitor display
parameter 2
The rules for running the monitoring interface are the same as the shutdown monitoring interface, and will
not be repeated
Function
Parameter name
code
Digital keypad
P21.13
personalized setting
Load speed display
P21.14
factor
VFD500 high performance vector control frequency inverter user manual
Example of monitoring
interface (stop)
Monitor display
parameter 5
Description
Unit's digit: quick editing function
selection
0: invalid
1:Numeric frequency setting
2:Numeric torque setting
3:PID digital setting 0
Note: The quick editing function means
that if the current monitoring value is the
output frequency or command frequency
under the monitoring status, press the
[ENTER] key to enter the parameter
editing interface directly. The edited
parameters are set by the ones digit of
this function code.
Ten's digit: monitor pointer reset
selection
0: When the display status is in the
monitoring status from other status, or
when the running monitoring status and
stop monitoring status are switched, the
previously recorded monitoring pointer
position will be restored.
1: When the display status is in the
monitoring status by other status, or when
the monitoring status of running status
and stop status are switched, the monitor
pointer will be reset to the ones of P21.11
or P21.12.
Note: when power-on, the shutdown
monitoring pointer points to the P21.12
bits, the operation monitoring pointer
points to P21.11 bits
0.001~65.000
- 86-
★ skip when
meet 0
To monitor
display parameter
2
Default
Property
01
30.000