Installing A Secondary Riser Cage - HPE ProLiant DL388 Gen10 User Manual

Hide thumbs Also See for ProLiant DL388 Gen10:
Table of Contents

Advertisement

7.
Install any expansion cards, if needed.
8.
Connect any data cables to riser or expansion boards.
9.
Install the tertiary riser cage.
10. Connect cables to drive backplanes, if needed.
The installation is complete.

Installing a secondary riser cage

Prerequisites
Before you perform this procedure, make sure that you have the following items available:
The components included with the hardware option kit
T-10 Torx screwdriver
Procedure
1. Observe the following alert:
CAUTION: To prevent damage to the server or expansion boards, power down the server and
remove all AC power cords before removing or installing the PCI riser cage.
2. Power down the server.
3. Remove all power:
a. Disconnect each power cord from the power source.
b. Disconnect each power cord from the server.
4. Do one of the following:
Extend the server from the rack.
Remove the server from the rack.
5. Remove the access panel.
114
Hardware options installation