Checking before Installation

The following conditions must be satisfied for the installation.
Therefore, it is better to check the planned installation site before delivering the machine to user site.

Checking the Power Supply

1. Be sure to connect the power plug exclusively to an outlet that compiles with the following.
• USA
imagePRESS C270 Series : 120-127V +/-10%, 60Hz, 12A
imagePRESS C270 Series : 120-127V +/-10%, 60Hz, 12A
• EUR/Asia/Oceania/Korea
imagePRESS C270 Series : 220-240V +/-10%, 50/60Hz, 11A
imagePRESS C265 Series : 220-240V +/-10%, 50/60Hz, 10A
• China
imagePRESS C270 Series : 220-240V +/-10%, 50/60Hz, 11A
imagePRESS C265 Series : 220-240V +/-10%, 50/60Hz, 10A
• Taiwan
imagePRESS C270 Series : 110V-120V +/-10%, 60Hz, 10A+14A
imagePRESS C265 Series : 110V-120V +/-10%, 60Hz, 9A+11A
2. Be sure to install this equipment near an outlet so that the power plug can be disconnected right away in case of
emergency, and do not put anything around the power plug.

Checking the Installation Environment

1. The environment of the installation site must be in the range as shown below. Avoid installation near the faucet, water boiler,
humidifier or refrigerator.
Guaranteed range for operation/image Temperature: 10.0 to 30.0 deg C, Humidity: 20 to 80%
2. The machine must not be installed near a source of fire or in an area subject to dust or ammonium gas.
If the area is exposed to direct rays of the sun, provide curtains to the window.
3. Be sure to provide adequate ventilation of the room to keep the work environment comfortable. Room odor can be bothering
when running the machine for a long time in a poorly-ventilated room although the ozone amount generated while running
this equipment does not harm human health.

Points to Note at Installation

When installing this machine, note the following points.
1. When the machine is moved from a cold location to a warm location, condensation may occur, resulting in water
drops on the metal surfaces.
Use of the host machine when there is condensation may result in image failure.
After moving the machine from a cold location to a warm location, leave it unpacked for at least 2 hours or more to let it warm
up to room temperature before installation.
2. Be sure to work with 4 or more people when installing it.
CAUTION:
Be sure to first complete the installation of the host machine only, and then perform checking after power-on.

Points to Note When Moving This Host Machine

• When moving this host machine after having unpacked it, be careful by placing a plate, etc. on areas with steps to prevent
the casters from hitting those steps.
If the casters hit a step, the casters or the base plate may be deformed.
• Keep the fixation members and screws that were removed during unpacking or installation as they may be used to transport
the machine for relocation or repair.