8. Adjust the Paper Guides and tighten the 4 Fixation Screws.
9. Output a test print from the Multi-purpose Tray and check that the value is within the specified range.
< Cassette Pull-in Check >
1. If the Buffer Path Unit is installed, open the Buffer Front Cover.
2. Pull out the cassette 200 mm or more.
CAUTION:
The pull-in mechanism is activated by opening the cassette 200 mm or more.
4x
200 mm
105
2. Host Machine