3. Adjust the value of the following service mode.
COPIER > ADJUST > IMG-REG > MAG-H
• Setting range : -100 to 100 (0.01 % per increment)
NOTE:
• When the actually measured value is smaller than the nominal value :
When the value is increased by "1", the horizontal scanning magnification ratio is increased by 0.01%.
• When the actually measured value is larger than the nominal value :
When the value is decreased by "1", the horizontal scanning magnification ratio is decreased by 0.01%.
(L4 is fixed.)
• Example (in the case of A3 paper) : When Ly = 291, (291 / 292 - 1) x 100 = -0.342... (The value is rounded off to two decimal
places.)
When the actually measured value is smaller than the nominal value (292 mm), the value of the ratio becomes "- (negative)";
therefore, the value to enter is "+34".
4. Output a test print from the Cassette 3 and check that the value is within the specified range.
5. Write down the new adjustment value in the service label.
Ly
L4
Ly
L4