BUILD JOB WARNINGS

If the system detects an issue that may affect a job build, it displays one of the following warnings:
1.
Head has been changed. Consider tip calibration
Indicates a new head has been installed.
Run and verify a calibration part before building jobs. See
page
76.
2.
Change Model (or Support) Canister to ABS
Indicates a mis-match between loaded material and material for which the part (CMB) file was
processed.
Replace the flagged material canister with proper type.
3.
Need More Model (or Support) Mat'l (9.1
The total available material is less than the estimated amount for the part (CMB file).
If the system runs out of material before part completion, system will pause the build until
material is added.
Replace flagged material canister.
4.
Need both (or 4 for 4-bay system) canisters present..
Indicates that at least one operating canister bay does not have material loaded to the Ready
mode (flashing green LED).
System operation will not be significantly compromised by this condition. The air-dryer circuit
performs more efficiently when all operable bays are Ready.
Install canisters to the Ready mode for all operating canister bays.
5.
Replace Model (or Support) tip with T12..
Indicates a mis-match between installed tip and tip for which the part (CMB) file was processed.
Install the correct tip.
6.
Replace Worn Model (or Support) Tip..
The system tracks the amount of material extruded through a tip. You will receive this prompt
when tip performance may start to become compromised. (Tip-life prediction is an estimated
value. Many factors contribute to actual tip-life aside from amount of material extruded. Actual
tip-life may differ from predicted tip-life.)
Replace the flagged tip.
is set to
is set to
54.
>Locate Part Start..
Demo Bounding Box
Continue..
or
Locate Part Start
to initiate the part build.
(system default), the part build will initiate (an Auto Z
NO
, you are offered the following choices:
YES
to view or change the part build start
(or other material)..
more)..
35
"Display Units"
"XY and Z Tip Offset - Manual Start" on

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fortus 400mc

Table of Contents