7.
Model / Support Mat'l Incompatibility..
•
Model and support materials are not of compatible types.
•
Load correct material.
8.
Vacuum not present-Please check build sheet
Vacuum is below minimum for system operation.
•
•
Correct condition - often the result of a poorly positioned build sheet.
9.
Continue..
•
You can choose to ignore the warning and 'Continue' the build, but part build quality will be
unpredictable.
•
A warning generated from a mis-match of model/support compatibility or from low vacuum
cannot be bypassed.
INFORMATION AVAILABLE DURING A BUILD
The following information is displayed while building a job:
1st line: The name of the build job.
•
•
2nd line: The elapsed time and total estimated build time -displayed in hours and minutes.
•
3rd line: The material type and estimated total amount of material for the build. The build mode is
also displayed.
•
4th line: The current height of the job and final Z height of the job.
Note: Press ENTER to go to the System Status screen (see
page
55).
PAUSING OR ABORTING A JOB
1.
During a part build, the system can be paused:
A.
Automatically (canister runs out of material, failure detected, etc.)
Note: If an automatic pause occurs, press the HELP key to view the cause.
B.
Manually - press and hold the PAUSE key on the operator panel for 2 - 3 seconds.
2.
When the system is directed to pause:
A.
The current tool path is completed.
B.
The Z stage is lowered slightly.
C.
The head is parked.
D.
The user display will change to indicate the paused condition.
* Job: motor housing (Building)
* Build Time: 0:01 hr of 0:02 hr
* PC 0.1 in3 PC_S 0.1
> Modeler Status..
*
Job: clip4
>Resume Build <E>
Modeler Status..
Operator Control..
36
Mode:Normal
0.010 of 0.950 in
"System Status" on
(Paused)
| Abort Job..
| Auto Cool:
OFF