XY AND Z TIP OFFSET - MANUAL START

Note: If the support layer is not centered on the model layer, an XY and Z Offset
should be performed.
Note: Perform an
on page 75
1.
Build the Calibration Model.
A.
From the Main Menu select Operator Control and press Enter.
B.
Select Calibrate and press Enter.
C.
Select Calibration Job and press Enter.
2.
At completion of the calibration model, 'read' the model and calibrate the system by following
paragraphs 2. through 5. from
"Auto Tip-Tip Calibration (AutoCal Tip Offset) - Manual Start"
before XY and Z Offset.
Build Job..
>Operator Control..
Modeler Status..
Maintenance..
Unlock Door <E>
Load/Unload Mtl..
Change Tips/Mtl..
>Calibrate..
Set Z Stage Zero..
AutoCal Tips <E>
Tip Offset Value..
AutoHome XYZ <E>
"XY and Z Tip Offset Calibration" on page
|*Tips: Model T16
|*
Support T16
| Temp Control..
| Move Head/Stage..
|>Calibration Job <E>
76
69.