AUTO Z STAGE ZERO CALIBRATION - MANUAL START

Note: An Auto Z Stage Zero Calibration must be performed after running
"Manual Z Stage Zero" on page
calibration.
Note: Perform an Autohome XYZ before Z Stage Zero Calibration (Operator
Control > Calibrate > AutoHome XYZ).
1.
Make sure a build sheet is installed and verify that vacuum is present.
2.
Run the Auto Z Stage Zero Calibration.
A.
From the Main Menu select Operator Control and press Enter.
B.
Select Calibrate and press Enter.
C.
Select Set Z Stage Zero and press Enter.
D.
Select Auto Z Zero Calibrate and press Enter.
E.
The system performs an Auto Z Stage Zero Calibration. If Auto Z Stage Zero Calibration
fails, perform
Build Job..