Odometer Status; Material Status - Stratasys Fortus 360mc User Manual

3d production system
Hide thumbs Also See for Fortus 360mc:
Table of Contents

Advertisement

ODOMETER STATUS

The system tracks and displays the total amount of material extruded through a liquefier tip since it was last
replaced. To view the tip odometers:
1.
From the Main Menu select
2.
Select
Tip Status

MATERIAL STATUS

You can find the current status of each material canister.
1.
From the Main Menu select
2.
Select
Material Status
Modeler Status
Build Job..
Operator Control..
>Modeler Status..
Maintenance..
and press ENTER. The current status of the tips is displayed.
Temperatures..
Material Status..
>Tip Status..
Machine State
*
Mat'l amount
*Model tip
:
13.0 in3
*Support tip :
54.0 in3
*Tips: Model <T16>
Modeler Status
Build Job..
Operator Control..
>Modeler Status..
Maintenance..
and press ENTER. All active canisters are shown.
Temperatures..
>Material Status..
Tip Status..
Machine State
** Model
1:
PC
*
Model
2:
** Support 1:
PC_S
*
Support 2:
Type of
Material
and press ENTER.
|*Tips: Model T16
|*
Support T16
Support <T16>..
and press ENTER.
|*Tips: Model T16
|*
Support T16
56.4
in3
(Loaded)
in3
(None)
21.4
in3
(Loaded)
in3
(None)
Remaining
Status of each: None, Ready,
Volume
Loaded, At Head, Empty,
Misloaded, No Read
56

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fortus 400mc

Table of Contents