6.
If changing material type, follow the procedures outlined in
"Canister Installation" on page
7.
If the liquefier tips are to be changed:
Warning: Always use an approved ladder or step stool when working with
components under the top hood.
A.
Open the top door and top hood.
B.
Place the head in the head maintenance bracket (refer to
page
15).
C.
Loosen the two captive screws that clamp each liquefier tip in place. Remove the tips.
Figure 4-5:
Liquefier Retaining Screws
D.
Place the new liquefier tips in the head. Tighten the clamp screws.
Note: Make sure the tips are fully inserted into heater block before tightening the
clamp screws
"Liquefier Tips and Slice Heights" on page 18
See
Figure 4-6:
Tip Installation
E.
Remove the head from the maintenance bracket and place it back in the gantry. Tighten the
two captive screws - close the top hood and top door.
Note: Make sure the filament tubes, umbilical cable, and air hose are not tangled
and are routed correctly.
8.
Choose
Select Materials/Tips..
41.
(Figure
4-6).
Unload Model and Support.. <E>
*2. Insert new canisters (if required)
*3. Install tips
>Select Materials/Tips..
"Removing Canisters" on page 40
"Head Maintenance Bracket" on
Liquefier Clamp
Screws
for tip selection and material compatibility.
Make sure Tip is
fully inserted into
block.