Stratasys Fortus 360mc User Manual page 80

3d production system
Hide thumbs Also See for Fortus 360mc:
Table of Contents

Advertisement

F.
Continue to check and adjust for XY offset until the calibration toolpath is centered at 0 for
the X and Y axis.
Figure 6-1:
Calibration Model - English Units
+ X
Figure 6-2:
Calibration Model - Metric Units
+X
Tip Offset Adjustment Indicators
- Y
Example: Best
Centered Position
+ Y
- Y
Tip Offset Adjustment Indicators
Example: Best
Centered Position
+ Y
70
X - Y Support Calibration
Toolpath
X - Y Alignment
Indicators
- X
Z Calibration Box
This example
requires an
adjustment to Y of -
0.002 in.
The X axis requires
no adjustment
X - Y Support
Calibration Toolpath
X - Y Alignment
Indicators
-
X
Z Calibration Box
This example
requires an
adjustment to Y of -
0.05 mm.
The X axis requires
no adjustment