Stratasys Fortus 360mc User Manual page 70

3d production system
Hide thumbs Also See for Fortus 360mc:
Table of Contents

Advertisement

3.
Incrementally Moving the Z Stage and Head.
A.
Set the amount of movement the Z Stage and Head will move with each movement
command.
i.
From the Operator Control Panel, select Operator Control and press ENTER.
ii.
Select Move Head/Stage and press ENTER.
iii.
Select Move Relative and press ENTER.
iv.
Select Set Distance and press ENTER.
Press the ENTER to change the distance the Z Stage and Head will move with each movement
command. Each time the ENTER key is depressed the amount of movement will change. The
available distance options are: 0.001, 0.010, 0.100 and 1.000 inches (0.01, 0.10 and 1.0 and 10 mm).
Note: The current position of the head and stage are displayed on the last line.
The current values are based on the following coordinate system. Z = 0.0 when
the model tip is on the build sheet, X = 0.0 on the left side of the oven, and Y =
0.0 at the front of the oven.
Warning: When moving the Z stage, be careful not to run it into the head. When
the Z stage gets close to the top, toggle the set distance to 0.010 (0.254 mm) or
0.001 inches (0.0254 mm).
B.
To move the Z Stage:
Note: Each time a number key is depressed, the Z Stage will move the distance
set in
step 3. A.
Note: Z Stage movement is relative to the current position.
Build Job..
>Operator Control..
Modeler Status..
Maintenance..
Unlock Door <E>
Load/Unload Matl..
Change Tips/Matl..
Move Head to Service Location <E>
Move Head to Center-Front Location<E>
Move Z Stage to Bottom <E>
>Move Relative..
>Set Distance=
0.100 in <E>
*Move Head: +X <6> -X<4> +Y <2> -Y <8>
*Move Z Stage:
+Z <9> -Z <3>
*Current: X: 0.000
|*Tips: Model T16
|*
Support T16
| Calibrate..
| Temp Control..
|>Move Head/Stage..
Y: 0.000
Z: 0.000
60

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fortus 400mc

Table of Contents