MANUAL CALIBRATION

MANUAL Z STAGE ZERO

Note: If the Auto Z Stage Zero calibration fails, Manual Z Stage Zero Calibration
must be performed. This procedure manually sets the model liquefier tip to the Z
Zero location.
1.
Install a new build sheet and verify that vacuum is present.
2.
Run Manual Z Stage Zero Calibration
A.
From the Main Menu select Operator Control and press Enter.
B.
Select Calibrate and press Enter.
C.
Select Set Z Stage Zero and press Enter.
D.
Select Set Manual Z Zero and press Enter.
Set Z Stage Zero..
AutoCal Tips <E>
>Tip Offset Value..
AutoHome XYZ <E>
*Delta
X:0.0000
Y:0.0000
>-X
0.00
<E>
|
-Y
0.00
<E>
|
-Z
0.00
<E>
|
Build Job..
>Operator Control..
Modeler Status..
Maintenance..
Unlock Door <E>
Load/Unload Mtl..
Change Tips/Mtl..
>Calibrate..
>Set Z Stage Zero..
AutoCal Tips <E>
Tip Offset Value..
AutoHome XYZ <E>
>Set Manual Z Zero <E>
Modify Current Z Zero..
Auto Z Zero Calibrate <E>
| Calibration Job <E>
Z:0.0000
+X
0.00<E>
+Y
0.00<E>
+Z
0.00<E>
|*Tips: Model T16
|*
Support T16
| Temp Control..
| Move Head/Stage..
| Calibration Job <E>