xi.
If user placement is set to NO (system default is NO), the third line will read: Load and Calibrate..
Press ENTER
xii.
If user placement is set to YES, the third line will read: Select Calibration Part Position..
Press ENTER.
a.
Make placement selections (
b.
information see
Then select
c.
xiii.
Selecting Load and Calibrate.. initiates a sequence of automated system calibration and
material load.
xiv.
The oven and oven temperature must stabilize. Oven stabilization times for the material you are
running are listed in Table 4-1.
Table 4-2:
Oven Stabilization Times (in hours)
Current Oven
Temp.
ABSi ABS-M30
Room temp.
4
ABS-M30, ABSi
---
Auto Cool-Down
ABS-ESD7
---
ASA
---
Nylon 12
---
PC-ABS
4
PC
4
Ultem* 9085
6
Ultem 1010
6
PPSF
6
Reset Model in3
Reset Supp. in3
>Load and Calibrate..
Unlock Door
<E>
Reset Model in3
Reset Supp. in3
>Select Calibration Part Position..
Unlock Door
<E>
Locate Part Start..
"Part Build Location" on page
Locate Part Start..
Demo Bounding Box
>Load and Calibrate..
Load and Calibrate..
*
Waiting h:mm to stabilize
** Actual
100 C Setpoint: 225 C
>Unlock Door <E>
Calibrate Immediately <E>
Material Type Being Installed
ABS-
ESD7
ASA
4
4
---
---
---
---
---
---
---
---
---
---
---
---
4
4
4
4
6
6
6
6
6
6
<E>
633.5 ()
<E>
182.7 ()
<E>
633.5 ()
<E>
182.7 ()
54.
<E>
|
Nylon 12 PC-ABS
4
4
4
---
4
---
4
---
4
---
4
4
4
---
4
4
4
6
6
4
6
6
4
6
6
6
51
,
Demo Bounding Box
*
**
*
Ultem*
Ultem
PC
9085
1010
4
8
4
6
4
6
4
6
4
6
4
6
---
4
4
---
4
4
4
4
- for more
PPSF
8
8
6
6
6
6
6
6
6
6
6
6
4
4
4
4
---
---
---
---