AUTO TIP-TIP CALIBRATION (AUTOCAL TIP OFFSET) - MANUAL START

Note: An Auto Tip-to-Tip Calibration must be performed if the initial automatic
calibration fails. Use this procedure to manually initiate the calibration.
"Auto Z Stage Zero Calibration - Manual Start" on page 74
before running the Auto Tip-to-Tip Calibration.
1.
Run Auto Tip-to-Tip Calibration.
A.
From the Main Menu select Operator Control and press Enter.
B.
Select Calibrate and press Enter.
C.
Select AutoCal Tips and press Enter.
D.
The system automatically calibrates the tips in the Z direction. Calibration time is about 5
minutes. While running, the display will show:
E.
At completion of the calibration, the display will show:
2.
Run
"XY and Z Tip Offset - Manual Start" on page
Build Job..
>Operator Control..
Modeler Status..
Maintenance..
Unlock Door <E>
Load/Unload MT..
Change Tips/MT..
>Calibrate..
Set Z Stage Zero..
>AutoCal Tips <E>
Tip Offset Value..
AutoHome XYZ <E>
* Tip to Tip Calibration Activity *
* Press <ESCAPE> to Abort Calibration *
* Tip to Tip Calibration Activity *
* Calibration Done: Press <MENU> Key *
|*Tips: Model T16
|*
Support T16
| Temp Control..
| Move Head/Stage..
| Calibration Job <E>