7.
Secure the XY Gantry:
Warning: Use an approved safety ladder to access the hood.
A.
Open the hood door and hood lid.
B.
Manually position the gantry in the left front corner of the XY table.
Caution: Do not use the head service handle to secure the XY Gantry. Damage
to the head could occur.
C.
Using several wire ties, secure the head to the frame.
Figure 2-6:
Securing the XY Gantry
Tie Wraps
8.
Reinstall and secure all panels.
9.
Raise the support feet located near each caster by loosening the locknut on each foot
7).
Figure 2-7:
System Casters
Caution: If the system will be rolled over floor seams or bumps, do not roll the
system on the casters. Use an appropriate lifting device.
Caution: If a forklift is used to lift the system, use it in accordance with the
specifications in the site prep guide.
(Figure
2-6)
Locknut
9
(Figure 2-

Advertisement