Connection Summary - Minimum System Wiring - Baldor FDH1A05TB-EN20 Installation Manual

Table of Contents

Advertisement

4.5 Connection summary - minimum system wiring

As a guide, Figure 43 shows an example of the typical minimum wiring required to allow the
FlexDrive
AC power
L
L
N
N
E
Star
point
PE
Motor
** Model shown: FDH2A07TR-RN23:
This model requires an external regeneration resistor and customer supplied 24V supply - see sections 3.6 and 3.4.7.
Some models contain an internal 24V supply and/or an internal regeneration resistor.
Demand input may be differential or single ended. See section 4.2.1.
The encoder output (X7) would normally be connected to a motion controller (not shown).
Motor represents a typical Baldor BSM motor. Linear motors may also be controlled by FlexDrive
Shield earth/ground clamps are not supplied.
MN1902
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
II
to control a motor.
Filter
L
N
E
If the filter has no output
earth/ground terminal, earth
wire may be connected
directly to the star point.
Motor
power
U V W
Figure 43 - Example minimum system wiring
AC
power
in
Shield earth/ground clamp
attached to enclosure backplane
+24V
0V
Customer
supplied
To regen
24V**
resistor
(Dynamic
brake)**
www.baldormotion.com
Host PC
COM
Serial communication
Drive
enable
switch
+24V 0V
Demand
input
II
.
Input / Output 4-19