3.9.9 Preventing a program running at startup
II
Flex+Drive
only:
If switches 5 and 9 are set to On and switch 8 is set to Off, any program already in the
II
Flex+Drive
that contains an Auto command will be prevented from running automatically at
startup.
It is possible for normal (Baldor Binary Protocol) serial communication to be lost if bit 5 of the
Mint keyword COMMSMODE has been set. This can occur when alternative communication
protocols have been used. This DIP switch procedure will clear bit 5, restoring normal serial
communication.
1.
Remove
power.
Figure 23 - Preventing the Auto command from running a stored Mint program, or restoring
3-36 Basic Installation
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
2.
5
On
Off
8
9
On
normal serial communication
www.baldormotion.com
3.
Reapply power. Mint program
with Auto command will not run.
MN1902