4.4.4 Using RS232 cable

CAUTION: The serial connector on the FlexDrive
Front panel DIP switch 10 must be in the Off position to select RS232 operation.
The FlexDrive
57.6Kbaud
H
1 start bit
H
8 data bits
H
1 stop bit
H
No parity
H
Hardware handshaking lines (RS232) RTS and CTS must be connected.
H
This configuration can be changed if required. The RS232 connections are brought out onto a
9-pin male D-type connector. The RS232 port is configured as a DTE (Data Terminal
Equipment) unit. Both the output and input circuitry are single ended and operate between
±12V. The port is capable of operation at up to 57.6Kbaud.
FlexDrive
(DTE)
The maximum recommended cable length is 3m (10ft) at 57.6KBaud (the factory preset rate).
When using lower Baud rates, longer cable lengths may be used up to maximum of 15m (49ft)
at 9600 Baud.
4-16 Input / Output
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
RS232 or RS485 / RS422. Pin 9 is used to carry +8V for powering certain
Baldor keypad peripherals. Ensure that pin 9 is not connected to
earth/ground or to equipment that could be damaged by the +8V supply.
A suitable cable is available from Baldor, catalog number CBL001-501.
II
has a full-duplex RS232 serial port with the following preset configuration:
X6
RXD 2
TXD 3
II
GND 5
RTS 7
CTS 8
shield to connector
Figure 39 - RS232 serial port connections
II
COM
2 RXD
3 TXD
5 GND
7 RTS
8 CTS
Connect overall
backshell.
www.baldormotion.com
(X6) can be configured as either
9-pin
Computer
COM Port
(DCE / DTE)
MN1902