Baldor FDH1A05TB-EN20 Installation Manual page 103

Table of Contents

Advertisement

8.1.1 AC input power and motor output - single-phase models
115VAC (Catalog number FDH1... / FPH1...)
Nominal input voltage
Minimum input voltage (recommended / absolute)
Maximum input voltage
Nominal input current
@ maximum rated output current
Nominal DC-Bus voltage
Minimum operating DC-Bus voltage
Maximum operating DC-Bus voltage
Overvoltage safety trip
230VAC (Catalog number FDH2... / FPH2...)
Nominal input voltage
Minimum input voltage (recommended / absolute)
Maximum input voltage
Nominal input current
@ maximum rated output current
Nominal DC-Bus voltage
Minimum operating DC-Bus voltage
Maximum operating DC-Bus voltage
Overvoltage safety trip
* As input voltage decreases, DC-Bus ripple voltage increases. This can cause a deterioration
of drive performance.
All single-phase models (Catalog numbers:
Output voltage (line-line)
@VDC-Bus=320V
Nominal phase current (±10%)
Peak phase current (±10%)
2.5A & 5A: for 2.4s (+0.5s / -0s)
7.5A:
for 1.25s (+0.5s / -0s)
Nominal output power
Efficiency
Output frequency
Nominal switching frequency
8-2 Specifications
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
FDH1... / FPH1... and
FDH2.../ FPH2...)
www.baldormotion.com
Unit
2.5A
5A
VAC
115
97 / 75*
125
A
6.25
12
RMS
VDC
160
135
176
210
Unit
2.5A
5A
VAC
230
220 / 75*
250
A
6.25
12
RMS
VDC
320
306
350
420
Unit
2.5A
5A
V
0 - 230
RMS
A
2.5
5.0
RMS
A
5
10
RMS
kVA
1.01
2.17
%
>95
Hz
0 - 500
kHz
8.0
7.5A
18
7.5A
18
7.5A
7.5
15
2.99
MN1902

Advertisement

Table of Contents
loading

This manual is also suitable for:

Flex+drive ii

Table of Contents