D.1.6 Wiring of shielded (screened) cables
Remove the outer insulation
to expose the overall shield.
Clamp should provide 360°
contact with the cable.
FlexDrive
II
X8
REF+
1
REF-
6
2
COS+
7
COS-
SIN+
3
SIN-
8
AGND
5
II
FlexDrive
X8
1
CHA+
6
CHA-
2
CHB+
7
CHB-
3
CHZ+
8
CHZ-
11
+5V
13
DGND
II
FlexDrive
X9
1
CHA+
6
CHA-
2
CHB+
7
CHB-
3
CHZ+
8
CHZ-
9
+5V
5
DGND
MN1902
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
or
Figure 57 - Earthing/grounding cable shields
Cable
Connect overall shield
to connector backshell.
Figure 58 - Resolver cable grounding
Cable
Connect overall shield
to connector backshell.
Figure 59 - Encoder signal cable grounding
Cable
Connect overall shield
to connector backshell.
Figure 60 - Auxiliary Encoder cable grounding
Flat or p-type
conductive
clamp
Twisted pairs
Twisted pairs
Twisted pairs
www.baldormotion.com
Resolver Connector
Housing
Connect overall shield
to connector backshell.
Encoder Connector
Housing
Connect overall shield
to connector backshell.
Auxiliary Encoder
Housing
Connect overall shield
to connector backshell.