3.9.6 Switch 9 - MODBUS select

Switch 9 enables the MODBUS serial protocol the next time the FlexDrive
This affects the value of the Mint keyword SERIALPROTOCOL. Enabling MODBUS disables
the Host Comms Protocol (HCP), so attempts to access the drive's comms array over the
serial connection (using a serial HMI panel for example) will no longer work.

3.9.7 Switch 10 - RS232/RS485 select

Switch 10 selects RS232 communications (Off) or RS485/RS422 (On) the next time the
FlexDrive

3.9.8 Factory settings

If switches 1-4 are all in the On position and switch 8 is set to Off, the FlexDrive
to its preset factory settings at power on (or whenever the processor is reset by Mint
WorkBench).
CAUTION: Use this function carefully - it will erase your drive setup information.
When using the SW1 DIP switches to reset the FlexDrive
parameters including the node number and serial communications baud rate will be reset.
In Mint WorkBench, this means it will be necessary to rescan for the FlexDrive
new project) to enable communication. It will also be necessary to re-tune your motor and
drive.
1.
Remove
power.
Figure 22 - Resetting the FlexDrive
The Mint keyword FACTORYDEFAULTS can also be used to reset the FlexDrive
defaults. However, it will not reset the node number or serial communications baud rate. See
the Mint help file for details.
MN1902
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
II
is power-cycled.
2.
1
2
3
4
Off
II
to its factory defaults, all
3.
Reapply
power.
On
On
On
On
8
II
to its factory default settings
www.baldormotion.com
II
is power-cycled.
II
will be reset
II
(by starting a
II
4.
FlexDrive
will
be reset to its
preset factory
settings.
II
to its factory
Basic Installation 3-35

Advertisement

Table of Contents
loading

This manual is also suitable for:

Flex+drive ii

Table of Contents