4.3.5 Digital outputs - X3

CGND 8
18
20
Each optically isolated PNP output is designed to source current from the USR V+ supply as
shown in Figure 31. The maximum saturated voltage across any of the outputs when active is
1.0VDC, so they can be used as TTL compatible outputs. If the outputs are used to directly
drive a relay, a suitably rated flyback diode must be fitted across the relay coil, observing the
correct polarity. This is to protect the output from the back-EMF generated by the relay coil
when it is de-energized. The outputs can be written to directly using the Mint keyword OUTX
(for example OUTX.2=1). The sense of the outputs can be configured in Mint WorkBench, and
their states are displayed in the Spy window.
MN1902
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
Location Connector X3
Pin Name
18 DOUT0
19 DOUT1
20 DOUT2
Description Three general-purpose optically isolated digital outputs.
II
FlexDrive
OUTX.x
NEC PS2562L-1
Figure 31 - X3 digital output circuit - DOUT0 shown
Output current: 50mA maximum each output
Update intervals:
Immediate: Software (Mint programs)
LOOPTIME (default 1ms): DRIVEENABLEOUTPUT,
DRIVEOKOUTPUT and GLOBALERROROUTPUT functions.
Outputs controlled by functions MOVEOUT, MOVEOUTX,
MOVEPULSEOUTX, PULSEOUTX.
Programmable: PLC Task functions