7.2.2 DB On (Regeneration) LED

The front panel DB On LED indicates regeneration activity.
Yellow
Off

7.2.3 Communication

Problem
Status display is
blank
Mint WorkBench
fails to detect the
FlexDrive
detects "No
controller found.
Communication
fault on COMx".
MN1902
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
Power is being dissipated into the regeneration resistor
No regeneration is occurring.
Check
Check that the customer supplied 24VDC power supply is connected
correctly to connector X1 and is switched on.
On models with an internally generated 24VDC supply, check that the
AC power supply is connected correctly to connector X1 and is
switched on.
Ensure that the FlexDrive
illuminated (see section 7.2).
II
- it
Check that the serial cable is connected between the PC's COM port
and connector X6 on the FlexDrive
Check which PC COM port is being used, or use the "Scan all serial
ports" option to locate the FlexDrive
Check the wiring of the serial cable or try an alternate cable. Check
that DIP switch 10 (RS232/RS422) is set correctly (see section 3.9.7).
On the PC, try an alternative COM port.
Confirm that a mouse driver or other serial device is not conflicting
(using the same COM port) as Mint WorkBench.
Does the FlexDrive
firmware and the download failed, the controller may not have
firmware. If this has happened, the Status display will show a minus
sign (-) and flash the decimal point repeatedly.
Check that the selected Baud rate is supported by the PC and
II
FlexDrive
If the "Only scan COMx" option is selected in Mint WorkBench, check
that the correct COM port is selected.
If the "Search up to Nodexx" option is selected in Mint WorkBench,
check that the FlexDrive
Do you have multiple nodes on the bus? If so, they must all be set to
the same Baud rate. Mint WorkBench scans through all the node Id's
at different Baud rates. When it finds a node, it will only continue to
scan for other nodes at the same Baud rate.
II
is powered and the Status display is
II
have firmware in it? If you tried to download new
.
II
node number is not higher than this value.
www.baldormotion.com
II
.
II
.
Troubleshooting 7-5