3.6 Regeneration resistor (Dynamic Brake resistor)

The 2.5A and 5A FlexDrive
15A, 20A and 27.5A FlexDrive
dissipate excess power from the internal DC bus during motor deceleration. When
regeneration causes the DC bus voltage to rise by more than about 10-50 volts (model
dependent) above the maximum allowable DC bus voltage, the regeneration resistor is
automatically connected. When this happens, the yellow DB On LED on the front panel of the
II
FlexDrive
will illuminate.
The FlexDrive
be used as a means of protecting the drive from regeneration, since the trip occurs at a much
higher voltage than the regeneration switching voltage. Allowing regeneration to cause regular
overvoltage trips increases the chance of permanent damage to the FlexDrive
R1
R2
* If required by the application, additional external resistors connected to R1 and R2 will be
connected in parallel with the internal resistor.

3.6.1 Controlling regeneration

Some regeneration resistor assemblies include an overload switch to indicate when too much
power is being dissipated by the resistor. This switch can be wired to a digital input on the
II
FlexDrive
. Using the Mint WorkBench Digital I/O tool, the input can be configured to be the
brake trip input. This allows the FlexDrive
The Mint keyword DBEXTTRIPINPUT can also be used to configure a digital input for this
purpose. On three-phase FlexDrive
controlled by further Mint keywords. These also begin with the letters DB..., for example
DBEXTPEAKPOWER. See the Mint help file for details.
Alternatively, a thermostatic switch on the regeneration resistor can be used to disconnect the
circuit breaker on the drive's ACpower input. This will prevent the drive from operating if the
regeneration resistor overheats.
3-20 Basic Installation
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
II
both have an internally fitted regeneration resistor *. For 7.5A,
II
, an external regeneration resistor must be installed to
II
has an additional emergency overvoltage trip system. However, this must not
Suitable regeneration resistors are listed in section A.1.9.
WARNING: A regeneration resistor may generate enough heat to
II
ignite combustible materials. To avoid fire hazard,
keep all combustible materials and flammable vapors
away from the resistors. The regeneration resistor
should be mounted near the top of an enclosure to
maximize heat dissipation. Baldor regeneration
resistors are neither internally fused nor thermally
protected and, under extreme conditions, can cause
a fire hazard if not suitably protected or rated for the
application.
II
to respond to resistor overload conditions.
models, the operation of the regeneration resistor can be
www.baldormotion.com
II
.
MN1902