Baldor FDH1A05TB-EN20 Installation Manual page 71

Table of Contents

Advertisement

4.4.6 Connecting Baldor HMI Operator Panels
Baldor HMI Operator Panels use a 15-pin male D-type connector (marked PLC PORT), but
II
the FlexDrive
handshaking then use the connections shown in Figure 41:
Figure 41 - Cable wiring if hardware handshaking is not required
If hardware handshaking is required then use the connections shown in Figure 42:
Figure 42 - Cable wiring if hardware handshaking is required
4-18 Input / Output
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
connector X6 is a 9-pin male D-type connector. If you do not require hardware
Baldor HMI
PLC PORT
RXD 2
TXD 3
GND 5
1
Baldor HMI
PLC PORT
CTS 11
RTS 10
RXD 2
TXD 3
GND 5
1
FlexDrive
X6
7 RTS
8 CTS
Twisted pair
3 TXD
2 RXD
5 GND
FlexDrive
X6
Twisted pair
7 RTS
8 CTS
3 TXD
2 RXD
5 GND