3.8.2 Drive enable - SW1 DIP switch

8

3.8.3 Drive enable command

The other action required to enable the FlexDrive
hardware.
Note: This method is explained here for your information, but cannot be completed until
you have installed the software and are ready to turn on AC power to the drive.
Please continue to read all sections in sequence. Do not turn on AC power until
you reach the appropriate instructions.
In software, a drive enable command must be issued. The easiest way to do this is by clicking
the Drive enable button
DRIVEENABLE=1 can be used. See the Mint help file for details.
In hardware, a digital input can be used to create the drive enable command. This can be
configured in Mint WorkBench using the Digital inputs tab of the Digital I/O tool. Alternatively,
the Mint keyword RESETINPUT can be used to select the required digital input. See the Mint
help file for details. Digital inputs DIN0 - DIN7 are sampled every 2ms, so if one is used to
provide the drive enable command it must be maintained for at least 2ms to ensure detection.
Another method is to use the Mint keyword DRIVEENABLEMODE. This allows the combination
of DIP switch 8 and the Drive Enable input to create the drive enable command. Both inputs
must become active. Provided one input is already on, as soon as the other input changes
from off to on (active), the drive will be enabled. See the Mint help file for details.
3-32 Basic Installation
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
To enable the FlexDrive
This switch provides a local enable/disable switch that can be useful
during testing.
The state of the drive enable DIP switch is displayed in the Mint
On
WorkBench Spy window. It can also be checked (but not set) using the
Mint keyword ENABLESWITCH. See the Mint help file for details.
See section 3.9 for full details of other DIP switch functions.
in Mint WorkBench. Alternatively, the Mint commands RESET or
II
the front panel DIP switch 8 must be set to On.
II
can be controlled either by software or
www.baldormotion.com