9
Phillips screw
Full height tape drive
Mounting bracket
Figure 9-14 Removing Full Height 8mm Tape Drive Mounting Brackets
Note – If not replacing the full height 8 mm tape drive with another drive,
install a cover plate over the empty drive bay. Then replace the panels and
power on the system using instructions given in Part 3—"Preparing for Service."
9.5 Half Height 8 mm Tape Drive
Figure 9-15 Half height 8 mm Tape Drive
There are five possible locations for the half height 8 mm tape drive in the
SPARCcenter 2000 system cabinet. See Figure 9-16. Refer to Appendix F for
location and SCSI addressing information.
9-12
SPARCcenter 2000/2000E Service Manual—June 1996