2.3 Using probe scsi

2-4
Code Example 2-1
The prtdiag Command (Continued)
2: <empty>
3: <empty>
Failed Field Replaceable Units (FRU) in System:
==============================================
SBus Card unavailable on System Board #7
Failed Field Replaceable Unit is SBus card 0
cpu-unit unavailable on System Board #8
Failed Field Replaceable Unit is SuperSPARC Module A
#
As shown above, prtdiag displays the status of system boards and
replaceable system board components:
System boards, by location
SuperSPARC modules, by number, location, and type (identified as
operating speed)
SIMMs, by quantity and locations (identified by group)
SBus cards, by location and type
Use this command to verify operation for a new or replacement SCSI-2 device
installed in the system.
1. Become superuser.
2. Use the appropriate command to halt the system.
Once the system is halted, several system messages display. When messages
finish, condition a or b below exists; respond as appropriate:
a. The "ok" prompt displays; proceed to step 3.
b. The screen below displays
Type b (boot), c (continue), or n (new command mode)
>
Type the following:
SPARCcenter 2000/2000E Service Manual—June 1996