2
2.3 Using probe scsi
2-4
Code Example 2-1
The prtdiag Command (Continued)
2: <empty>
3: <empty>
Failed Field Replaceable Units (FRU) in System:
==============================================
SBus Card unavailable on System Board #7
Failed Field Replaceable Unit is SBus card 0
cpu-unit unavailable on System Board #8
Failed Field Replaceable Unit is SuperSPARC Module A
#
As shown above, prtdiag displays the status of system boards and
replaceable system board components:
•
System boards, by location
•
SuperSPARC modules, by number, location, and type (identified as
operating speed)
•
SIMMs, by quantity and locations (identified by group)
•
SBus cards, by location and type
Use this command to verify operation for a new or replacement SCSI-2 device
installed in the system.
1. Become superuser.
2. Use the appropriate command to halt the system.
Once the system is halted, several system messages display. When messages
finish, condition a or b below exists; respond as appropriate:
a. The "ok" prompt displays; proceed to step 3.
b. The screen below displays
Type b (boot), c (continue), or n (new command mode)
>
Type the following:
SPARCcenter 2000/2000E Service Manual—June 1996