9-4
1/4-Inch tape drive
Insulator
CD-ROM drive
Figure 9-5
SunCD/SunCD Plus and 1/4-Inch Tape Drive Assembly
To install a SunCD, SunCD Plus, SunCD 2Plus, or SunCD Plus4 drive:
1. On the drive rear panel, locate the PARITY and ID SELECT pins. See
Figure 9-6.
2. Verify the jumpers are correct for SunCD Plus or SunCD 2Plus as
appropriate:
a. SunCD Plus:
Ensure jumpers are installed on the PARITY and PREVENT/ALLOW pins
only. Refer to Figure 9-6.
b. SunCD 2Plus:
Ensure a jumper is installed on TERM POWER only. Refer to Figure 9-6.
3. If there is a 1/4-inch tape drive installed in the upper position of the
mounting brackets, place the insulator sheet on the CD-ROM drive.
See Figure 9-5.