Sun Microsystems SPARCcenter 2000 Service Manual page 120

Hide thumbs Also See for SPARCcenter 2000:
Table of Contents

Advertisement

7
Power cord
7-14
4. Disconnect the power cord.
This is in the lower-center of the supply. See Figure 7-14.
Figure 7-14 Disconnecting the Power Cord
5. Remove the EMI box from the power supply. See Figure 7-15.
a. Remove two screws from the bottom lip of the box.
b. Loosen two captive thumbscrews at the top of the box.
c. Allow the box to drop far enough to expose the cables.
6. Unplug the filter cable from the top connector on the power supply.
See Figure 7-15.
7. Remove the power sense cable from J1.