Deleting A Laser File; Liteloc ™ Sensor-To-Screen Calibration; Liteloc Sensor-To-Screen Calibration: Workflow - Christie CineLife+ CP4415-RGB User Manual

Hide thumbs Also See for CineLife+ CP4415-RGB:
Table of Contents

Advertisement

Deleting a laser file

Delete a laser file when the configuration is no longer required.
1. In the left navigation menu, select Laser Settings > Laser Power/LiteLOC Setup.
2. Select the Display White Test Pattern slider.
3. In the Laser File list, select the file to delete.
4. Select Delete.
5. To confirm the deletion, select Delete.
LiteLOC
sensor-to-screen calibration
The LiteLOC sensor-to-screen calibration is performed in the factory under specific setup conditions
which include the type of lens, screen, and the spectroradiometer used for measuring screen color and
brightness.
Your projector's setup conditions may not match the factory setup which may result in an discrepancy
in color accuracy. Upon first installation, check the accuracy of the color point and if unsatisfactory,
perform this calibration. Doing this calibration captures all the variables of your setup and achieves the
best results. By doing this calibration, you will not overwrite the factory calibration. Once satisfied,
some scenarios may exist in which you may need to re-do the calibration in the future.
Re-doing this calibration is required if the following is replaced:
Color sensor board
Christie recommends re-doing this calibration if any of the following are replaced:
Light engine
Lens
LOS (laser optical subsystem)
Screen
Port window
Any other optical components in the optical path between the LOS and the screen
After replacing these components, check the accuracy of the color point and if unsatisfactory, re-do
this calibration.

LiteLOC sensor-to-screen calibration: Workflow

Identify the recommended order for performing the sensor-to-screen calibration.
Create a new calibration file (on page 50).
Recalibrate the calibration file (on page 51), if required.
Edit the existing calibration file parameters (on page 52) on the Sensor-to-screen menu, if
required.
Verify the calibration (on page 52), if required.
Add the calibration file to the Channel Setup (on page 53).
CineLife+ User Guide–CP4415-RGB, CP4420-RGB, CP4435-RGB, CP4440-RGB, CP4450-RGB, CP2420-Xe, CP4420-Xe
020-103073-06 Rev. 1 (03-2022)
Copyright
©
2022 Christie Digital Systems USA, Inc. All rights reserved.
Managing the laser light source
49

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents