Examples
Move the lens to position 500 on the horizontal axis:
(LHO 500)
LIF–Total Project Hours
Display the total number of hours the projector has been used.
Commands
Command
Description
LIF+TPHS
Returns the current number of hours the projector has been used.
(Read-only)
LLC–Light Sensor Calibration
Calibrates the light sensor. Complete a calibration whenever the light source is replaced.
Commands
Command
Description
LLC 1
Calibrates the light sensor. (Write-only)
LLC+STAT?
Returns the current light sensor calibration setting.
Examples
Initiate the calibration cycle:
(LLC 1)
LOC–Localization Language
Sets the language for the on-screen display (OSD).
Commands
Command
Description
LOC+LANG <value>
Sets the on-screen display language.
GS Series 599 Serial Commands Technical Reference
020-102403-02 Rev. 1 (04-2017)
Copyright
2017 Christie Digital Systems USA Inc. All rights reserved.
©
Serial API commands
Values
Values
1 = Calibrated
Values
0 = English Default
1 = Simplified Chinese
2 = French
3 = German
36