4.29 Clock ID/Status (CLK_ID)

4.29.1 Address
Register
CLK_ID
033h
4.29.2 Function
The CLK_ID register is used to identify the arrangement of the clock control registers.
Software should check CLK_ID register before attempting to interpret/control the clock
control registers.
4.29.3 Diagram
Bits
7
R
W
NONE
4.29.4 Fields
Field
7-4
Reserved.
-
3-0
System Clock ID = 0000 (NONE)
ID
CLK0= SYSCLK is fixed on this system.

4.30 Reset Control Registers

QorIQ LS1028A Reference Design Board Reference Manual, Rev. A, 02/2018
NXP Semiconductors
6
5
4
0000
Confidential Proprietary
Chapter 4 Qixis Programming Model
Offset
3
2
Function
1
0
ID
0000