4.13.4 Fields
Field
7-4
Reserved.
-
3
Software Fault (CTL[FAIL] was set).
CTL
2
Reserved.
-
1
Temperature Fault:
TWARN
0= The temperature is within normal limits.
1= The temperature has exceeded warning limits.
NOTE: This signal may be asserted by either SA56004 thermal monitor. The temperature limits depend
upon software programming.
0
Temperature Alert:
TALERT
0= The temperature is within normal limits.
1= The temperature has exceeded fault limits.
NOTE: This signal may be asserted by either SA56004 thermal monitor. The temperature limits depend
upon software programming.
4.14 Presence Detect 1 (STAT_PRES1)
4.14.1 Address
Register
STAT_PRES1
00Bh
4.14.2 Function
The STAT_PRES1 register detects the presence and type of processor installed.
QorIQ LS1028A Reference Design Board Reference Manual, Rev. A, 02/2018
NXP Semiconductors
Function
Offset
Confidential Proprietary
Chapter 4 Qixis Programming Model
73