Advertisement

Commissioning
5.4 Establishing an online connection to the drive
3. Double click on "Update accessible devices".
The drive is displayed in the project tree.
If the communication parameters of the drive are set to factory settings (IP address 0.0.0., no
device name), then the default device name of the TIA Portal (in this case: "Accessible
device") and the MAC address are displayed.
Note
Assigning an IP address and device name for a drive
To be able to connect online with the drive, it is necessary to assign an IP address and a device
name.
4. Select the drive and, if necessary, assign an IP address and device name (see Chapter
"Assigning an IP address (Page 160)" and Chapter "Assigning PROFINET device names
(Page 162)").
The drive is displayed with a device name (here: drive_1) and an IP address.
If you cannot assign an IP address and device name, you may have to check the IP address of
your PG/PC. This must also lie in the same address range as the address of the drive (see also
Chapter "Setting up the preferred PG/PC interface (Page 164)").
Result
• You have found the drive in the PROFINET subnet.
• You have assigned an IP address and a device name to the drive.
5.4.3.3

Assigning an IP address

Before you connect your PG/PC with your drive online, you must assign an IP address to the
PROFINET interface X150 of your drive.
160
Commissioning with Startdrive
Commissioning Manual, 06/2020, 6SL3097-5AA10-0BP2