4. Interconnect the "Open brake command" (p0899.12) signal source to the required
parameters. Several connections are possible.
5. To open the "Closing the brake (Page 268)" dialog, click "Close brake".
Make the required settings in the dialog.
6. Interconnect the "Close brake command" (p0899.13) signal source to the required
parameters. Several connections are possible.
The "Open brake" and "Close brake" settings are processed logically via the flip-flop. The "Open
brake" and "Close brake" signals are then present at the outputs of the flip-flop.
5.10.1.2

Opening the brake

Overview
The following describes how you can set the command for the forced opening of the holding
brake.
Parameterizing the "Open brake" command
To parameterize the command for the forced opening of the holding brake, interconnect the
signal sink "Unconditionally open holding brake" (p0855) for the command that is to
unconditionally open the brake.
The brake opens when this signal or the internal signal "Open brake" has the value "1".
Note
Prioritization of the commands
The "Unconditionally close brake" signal has a higher priority than the "Unconditionally open
holding brake" signal.