Electrical data of single-axis converter XCS*-W0023

Control voltage
Table 54: Control voltage supply data
Designation
Control voltage input
1)
Control voltage when using motor holding brake
with motor cable length < 50 m
Control voltage when using motor holding brake
with motor cable length > 50 m
Max. inrush current at 24 V supply
Pulse width of I
EIN3
Input capacitance
Maximum power consumption control voltage
input at U
N3
1) 2) 3) Comply with supply voltage for motor holding brake
Overvoltage
Overvoltage greater than 33 V has to be discharged by the appropriate elec-
trical equipment of the machine or installation.
Electrical equipment affected:
Mains voltage
Table 55: Mains voltage supply data
Designation
Mains frequency
Tolerance mains frequency
Maximum allowed mains frequency change
Rotating field condition
Short-circuit current rating
Nominal mains voltage
Mains voltage, single-phase
Three-phase mains voltage at TN-S, TN-C, TT
mains
Mains voltage, three-phase at IT mains
Mains voltage, three-phase at Corner-grounded-
Delta mains
Tolerance U
LN
Minimum inductance of mains supply (mains
phase inductance)
1)
Inrush current
Maximum allowed ON-OFF cycles per minute
Mains input continuous current at U
P
(three-phase)
2)
DC_cont
RE 62312-B, 03.2022
Connecting the Sytronix system SvP 7030 electrically
2)
3)
24V power supply units that reduce incoming overvoltage to the allowed
value.
Overvoltage protector at the control cabinet input, limiting overvoltage to
the permissible value. This, too, applies to long 24V lines that are run in
parallel to power cables and mains cables and that can absorb overvoltages
by inductive or capacitive coupling.
and
LN_nom
Sytronix SvP 7030 IMC
Symbol
Unit
U
V
N3
U
V
N3
U
V
N3
I
A
EIN3_max
t
ms
EIN3Load
C
mF
N3
P
W
N3
Symbol
Unit
f
Hz
LN
Hz
Δf
/Δt
Hz/s
LN
SCCR
A rms
U
V
LN_nom
U
V
LN
U
V
LN
U
V
LN
U
V
LN
%
L
µH
min
I
A
L_trans_max_on
I
A
LN
91 / 186
XCS*-W0023
24 ±20%
24 ±5%
26 ±5%
4
20
tbd
12.1
XCS*-W0023
50 ... 60
±2
2
None
42000
400
Not permitted
200 ... 500
200 ... 500
Not permitted
+10 / -15
40
tbd
20
7.4