K1
S1
S2
S4
S5
7.5.4
Control voltage
Control voltage for drive systems
Some components of a drive system have to be supplied with control voltage.
When selecting a control voltage supply, observe the requirements of the com-
ponents in the drive system:
● depending on the motor cable length and the use of motor holding brakes
● Power consumption of the drive controllers
● Power consumption of further consumers (e.g., motor holding brakes, digital
● Current carrying capacity of connection point for control voltage supply at
Control voltage supply
Determining the power requirement
Power requirement of the drive controller
The total power requirement of the control voltage supply of a drive controller
results from the sum of the following power values:
● Basic device (drive controller without connected encoders)
● Optional connection interfaces (e.g. communication, additional encoder
● Connected encoder systems
● External loads
For the configuration of your drive controller, see the nameplate and the type
code.
The tables below contain the individual power values required by the drive con-
troller. The power requirement of the supplying 24V power supply unit results
from the sum of these individual power values.
RE 62312-B, 03.2022
Connecting the Sytronix system SvP 7030 electrically
External mains contactor
Emergency stop
Axis end position
Power OFF
Power ON
the allowed mains input voltage tolerance
outputs)
the component for the purpose of looping through the control voltage to
other components
evaluation)
Sytronix SvP 7030 IMC
Bosch Rexroth AG
79 / 186
Need help?
Do you have a question about the rexroth Sytronix SvP 7030 IMC and is the answer not in the manual?
Questions and answers