Commissioning of the drive controller

The connection to the drive as well as commissioning with the help of the engi-
neering software IndraWorks Ds is described in detail in functional description
RE 62312-FK.
8.2

Recommissioning after standstill

Depending on the installation and ambient conditions, changes may occur
in the system which make recommissioning necessary. Among others, the fol-
lowing criteria may result in the necessity for recommissioning:
● Air in the hydraulic system
● Water in the hydraulic system
● Aged hydraulic fluid
● Other contamination
For recommissioning proceed as described in "Initial commissioning" above.
RE 62312-B, 03.2022
Check the lines for wear and damage before every startup.
In the case of an internal gear pump, fill the pressure side with filtered
hydraulic fluid. This is carried out via the suction, the pressure or the test
port (see figure above) depending on the installation orientation. In the
case of an axial piston unit, fill the housing of the pump with hydraulic
fluid. For information regarding a suitable connection, please refer to the
operating instructions of the system.
Bleed the pump as described in the data sheet of the pump.