9

Operation

9.1

General

● Ensure that the specified ambient conditions are adhered to during opera-
● Pay attention to noise, temperature and vibration on the system.
● After some time in operation, inspect the hydraulic fluid in the tank for the
Changes in the operating speed, temperature, increasing noise or high energy
consumption are signs of wear or damage to the machine or the Sytronix
system. In the case of any changes, proceed as described in ⮫ Chapter 14
"Troubleshooting" on page 173.
9.2

Operating mode

The system automatically switches to the standby/parameter mode after each
restart, if no error is detected or generated during starting.
9.3

Error mode

If an error or a warning occurs, eliminate the cause of error. Then you can
acknowledge the error message as follows:
● Press the [ESC] key
● Set digital input 5 at XG31.7 to high level
9.4

LED PF01 (device state)

PF01 LED
RE 62312-B, 03.2022
Overheating!
CAUTION
Risk of burning at hot components due too poor dissipa-
tion of heat as a result of dirt, dust and mist deposits on
the Sytronix system.
Regularly remove dust and dirt accumulations from
the Sytronix system.
tion.
formation of bubbles or foam on the surface.
Sytronix SvP 7030 IMC
LED PF01 (device state)
Bosch Rexroth AG
159 / 186

Advertisement