Venting of the control cabinet (basic principle)
Fig. 22: Venting of the control cabinet (basic principle)
1 Control cabinet
2 Air outlet
3 Heat dissipation
4 Device in the control cabinet
5 Control cabinet fan
6 Filter at the air inlet
Thanks to the filter at the air inlets only clean air gets into the control cabinet.
The control cabinet fan behind the air inlet transports air into the control
cabinet and generates overpressure in the control cabinet. The overpressure
prevents impure air from entering the control cabinet through, for example, any
leaky spots (leaky cable glands, damaged seals, ...).
Mounting orientations of components
Allowed mounting orientation of the components
Only the mounting orientation G1 is allowed for ctrlX DRIVE components.
RE 62312-B, 03.2022
Mounting the machine control cabinet components
Wrong installation orientation
NOTICE
Risk of damage to the components!
Only operate the components in their allowed installa-
tion orientation.
Sytronix SvP 7030 IMC
Bosch Rexroth AG
51 / 186