Polaris Virage TX 2000 Service Manual page 270

Service manual
Table of Contents

Advertisement

ELECTRICAL
Polaris Electronic Reverse Control (PERC)
PWC Electric Reverse Operation/Troubleshooting
W1RF FND VIFW
OF CONNECTOR
4BLU/WHT/WHT
5 GRY/OR
6GRN/WHT/WHT
1BLK
2 BLU/WHT
3 GRN/WHT
Motor Resistance
In Forward
or Reverse
0.8Q
In Neutral
2.6Q
CONTINUITY TO PIN 1 (GROUND)
CONTINUITY TO PIN 4 (FORWARD/REVERSE SWITCH CONTACT)
CONTINUITY TO PIN 6 (FORWARD/REVERSE SWITCH CONTACT)
SWITCH POSITION
Italicized text indicates reverse gate position.
The motor windings resistance is