ELECTRICAL
Oil Level Sensor Testing
Oil Level Sensor Troubleshooting
Problem: No oil level indication and/or low oil warning at MFD/MFI.
3.
Open electrical box and disconnect oil level sensor wires. Measure resistance of sender wires and compare
to specifications. Consult the appropriate wiring diagram for specifications and wire colors.
4.
Inspect all electrical connections including the pins in the harness connector on the back of the MFD.
Connections must be clean and tight. Refer to MFD troubleshooting tips at the end of this chapter for more
information.
Oil Level Sending Unit Resistance
Full (Float up) - 35 Ohms
Empty (Float down) - 240 Ohms
All readings ±10% at room temperature.