ELECTRICAL
Starter Motor
15
Starter Assembly
1.
Install brush plate to field magnet housing
aligning index tab.
2.
Install O-ring, two small phenolic spacers, large
phenolic washer, flat washer, lock washer, and
terminal nut.
3.
While holding brush springs away from brushes,
push brushes back and hold in place.
4.
Slide armature
into field
magnet housing.
Release brushes.
5.
Lightly grease drive end bushing and reinstall
drive end frame on armature. Inspect seal for
wear or damage.
Replace drive end cap if
necessary. Lip of seal faces needle bearing.
*Do not reuse. Replace with new parts.