Polaris Virage TX 2000 Service Manual page 232

Service manual
Table of Contents

Advertisement

ELECTRICAL
Charging System/Switch Testing - Virage TX / SLX / Pro 1200 / Genesis
Charging System Testing (Regulated Voltage)
1.
Turn multitester dial to volts DC (V— ) and connect leads across battery terminals.
2.
Start and briefly run engine at 3000 RPM. Measured voltage should be around 14.5 VDC. A higher reading
may indicate a regulator problem or a poor ground at the regulator heat sink. A lower reading may indicate an
excessive system load, alternator problem, or a faulty regulator.
3.
If DC Volt reading is low, charge and test battery and re-test.
NOTE: The regulator/rectifier is a solid state unit and no repair or adjustment is possible.
Start/Stop Switch Testing
1.
Set multitester to ohms (Q) position.
2.
Unplug MFD/MFI connector.
3.
Connect one of the test leads to the red/purple pin and the other lead to the yellow/red pin. Depress start
button. The reading should be .3 ohms or less. A high resistance or open reading indicates a faulty switch.
4.
Release start button. An open reading (OL) should be indicated. If low resistance is measured, replace the
switch.
Tether Switch Testing
1.
Set multitester to ohms (Q) position.
2.
Unplug stop switch connector (black/yellow and black wires).
3.
Connect one of the test leads to the black/yellow pin and the other lead to the black pin. Push kill button or
disconnect tether cord. The reading should be .3 ohms or less.
4.
Connect tether cord and release button. An open reading should be indicated. If not, replace the switch.
Polaris Sales Inc.
7.9
3/°°