Eps (Ethernet Protection Switching) - FibroLAN Falcon Gen-3 M-Class User Manual

Table of Contents

Advertisement

Falcon M-Class | User Guide
4.25

EPS (Ethernet Protection Switching)

The Ethernet (Linear) Protection Switch instances are configured here
The EPS is supported by the G.8031 standard
Figure 4-210: Ethernet Protection Switching
Table 4-183: Ethernet Protection Switching Parameters
Delete
EPS ID
Domain
Architecture
W Flow
P Flow
W SF MEP
P SF MEP
APS MEP
Alarm
Buttons
This box is used to mark an EPS for deletion in next Save operation.
The ID of the EPS. Click on the ID of an EPS to enter the configuration page.
Port: This will create a EPS in the Port Domain. 'W/P Flow' is a Port.
Port: This will create a 1+1 EPS.
Port: This will create a 1:1 EPS.
The working flow for the EPS - See 'Domain'.
The protecting flow for the EPS - See 'Domain'.
The working Signal Fail reporting MEP.
The protecting Signal Fail reporting MEP.
The APS PDU handling MEP.
APS is an acronym for Automatic Protection Switching. This protocol is
used to secure that switching is done bidirectional in the two ends of a
protection group, as defined in G.8031
There is an active alarm on the EPS.
Add New EPS: Click to add a new EPS entry
Refresh: Click to refresh the page immediately.
Save: Click to save changes.
Reset: Click to undo any changes made locally and revert to previously saved
values
351