4.22.10 Delay Measurements Bins forFD
A Measurement Bin is a counter that stores the number of delay measurements falling within a
specified range, during a Measurement Interval.
Figure 4-202: Delay Measurement Bins for FD
Bin
Threshold
Bin0
0 us
5,000 us
Bin1
Bin2
10,000 us
Bin3
15,000 us
4.22.11 Delay Measurements Bins for IFDV
A Measurement Bin is a counter that stores the number of delay measurements falling within a
specified range, during a Measurement Interval
Figure 4-203: Delay Measurement Bins for IFDV
Bin
Threshold
Bin0
0 us
Bin1
5,000 us
10,000 us
Bin2
Bin3
15,000 us
F-to-N :Far-end-to-near-end
N-to-F :Near-end-to-far-end
Refresh: Click to refresh the page immediately
Buttons
Save: Click to save changes
Reset: Click to undo any changes made locally and revert to
previously saved values
Back: Click to go back to this MEP instance main page
Range
0 us <= measurement < 5,000 us
5,000 us <= measurement < 10,000 us
10,000 us <= measurement < 15,000 us
15,000 us <= measurement < infinite us
Range
0 us <= measurement < 5,000 us
5,000 us <= measurement < 10,000 us
10,000 us <= measurement < 15,000 us
15,000 us <= measurement < infinite us